Model ABI Series
RS232 ports are becoming obsolete and present day computers are supplied only with USB & Ethernet ports.ln this situation, it becomes difficult to connect weight indicator with computers on RS232 communication. To overcome this problem, Antares has developed a weight indicator with USB port for interfacing with computer USB port.
Features
- USB device port for linking with computer
- Two Communication Ports
- Three Step Software Calibration for accurate weight display
- Smart Calibration to correct small errors in weight display
- Password Security
- Calibration Security Hardware Lock
- View Calibration Result
- Auto Zero Tracking & Weight Tracking
- Zero Band Control to reduce effects of structure errors on weighments.
- Zeroing Limit Field Settable as 4% of scale capacity or lower
- Serial Port Testing to test if serial port hardware on indicator is ok
- Option of Graphical LCD is also available with the weight indicator. It gives a smart look to the indicator & adds some value added features.
- RF communication in built to connect remote score board display (Wireless Communication)
Application
- Weighbridge
- Industrial Scales
Specifications:
Micro Processor
- 32 Bit processor
Processor Clock
- 50 Mhz
Power Supply
- SMPS with EMI/RFI filter and Spike Suppresser
A/D Converter
- Sigma Delta type 24 BIT ADC
Conversion Speed
- Internal 25 samples per second
Load Cell Excitation
- 8V DC with current capability to drive up to 12 load cells of 350 ohm input resistance
Signal Sensitivity
- 1.0 micro volts per division of weight (unit weight)
Keyboard
- 4 Key or optional 16 Key calibrations keyboard
Display
- 240 x 64 mm Graphical Display
Remote Display Port
- To connect optional 1/2inch, l inch, 2.3inch or 4inch bright red LED display
Serial Port – 1
- Isolated RS-232 serial port for computer interfacing or remote displays
Serial Port – 2
- USB device port for computer interfacing
Indications
- Buzzer for fault and data entry
Fuse
- Fl fuse 2.5 ampere for AC power input
Protection
- RFI/EMI filter for input power
- Spike Suppressor for input transients.
Optional
- 4-20mA Output