Model ABI Series

RS232 ports are becoming obsolete and present day computers are supplied only with USB & Ethernet ports.ln this situation, it becomes difficult to connect weight indicator with computers on RS232 communication. To overcome this problem, Antares has developed a weight indicator with USB port for interfacing with computer USB port.

Features

  • USB device port for linking with computer
  • Two Communication Ports
  • Three Step Software Calibration for accurate weight display
  • Smart Calibration to correct small errors in weight display
  • Password Security
  • Calibration Security Hardware Lock
  • View Calibration Result
  • Auto Zero Tracking & Weight Tracking
  • Zero Band Control to reduce effects of structure errors on weighments.
  • Zeroing Limit Field Settable as 4% of scale capacity or lower
  • Serial Port Testing to test if serial port hardware on indicator is ok
  • Option of Graphical LCD is also available with the weight indicator. It gives a smart look to the indicator & adds some value added features.
  • RF communication in built to connect remote score board display (Wireless Communication)

Application

  • Weighbridge
  • Industrial Scales

Specifications:

Micro Processor

  • 32 Bit processor

Processor Clock

  • 50 Mhz

Power Supply

  • SMPS with EMI/RFI filter and Spike Suppresser

A/D Converter

  • Sigma Delta type 24 BIT ADC

Conversion Speed

  • Internal 25 samples per second

Load Cell Excitation

  • 8V DC with current capability to drive up to 12 load cells of 350 ohm input resistance

Signal Sensitivity

  • 1.0 micro volts per division of weight (unit weight)

Keyboard

  • 4 Key or optional 16 Key calibrations keyboard

Display

  • 240 x 64 mm Graphical Display

Remote Display Port

  • To connect optional 1/2inch, l inch, 2.3inch or 4inch bright red LED display

Serial Port – 1

  • Isolated RS-232 serial port for computer interfacing or remote displays

Serial Port – 2

  • USB device port for computer interfacing

Indications

  • Buzzer for fault and data entry

Fuse

  • Fl fuse 2.5 ampere for AC power input

Protection

  • RFI/EMI filter for input power
  • Spike Suppressor for input transients.

Optional

  • 4-20mA Output